Skip to content

Getting Started

The App Object

The central entry point is App. It wires together all components:

from brinkhaustools.common import App

app = App(name="my-service")
app.start()

App creates these components by default:

Attribute Component Default config
app.shutdown ShutdownHandler always created
app.logging LoggingHelper data/logs/
app.settings Settings data/settings/settings_main.json
app.diagnosis SelfDiagnosisEngine always created
app.status StatusEngine always created
app.heartbeat HeartbeatEngine 300s default timeout
app.version VersionInformation helper/version.json
app.fleet StatusMonitor fleetManagementData/config.json

Pass None to skip any component:

app = App(
    name="my-service",
    settings_path=None,       # no settings file
    fleet_config_path=None,   # no fleet reporting
    version_file=None,        # no version tracking
)

Reading Settings

timeout = app.settings.get(["expert", "timeout"], default=300)
# or with dot-notation:
timeout = app.settings.get("expert.timeout", default=300)

Reporting Diagnostics

app.diagnosis.notify(code=1001, message="Database unreachable", critical=True)
# Later, when resolved:
app.diagnosis.clear(code=1001)

Heartbeat Watchdog

app.heartbeat.register("main-loop", timeout_sec=60)

while not app.shutdown.is_shutdown():
    app.heartbeat.register("main-loop", timeout_sec=60)  # refresh
    do_work()

Fleet Management

To report status and diagnostics to the BrinkhausFleetManager, create fleetManagementData/config.json:

{
    "fleetmanagement": {
        "customer_name": "my-customer",
        "machine": "machine-01",
        "broker": "fleet.brinkhaus-gmbh.de",
        "heartbeat_interval_sec": 60,
        "token": "fmt_..."
    }
}

The token is created in the FleetManager UI (Customers → Manage Tokens).

Device identity (optional)

Devices provisioned by Brinkhaus carry a fixed serial number. Add these keys to the same fleetmanagement section to send it, together with the name and inventory number the customer chose, in every heartbeat:

{
    "fleetmanagement": {
        "serial_file": "/etc/brinkhaus/serial",
        "display_name": "Lathe 1",
        "inventory_no": "INV-4711",
        "stream": "brinkhaus",
        "initial_password_scheme": "hmac-sn-v1",
        "initial_password_changed": false
    }
}

The serial is read from the first line of serial_file (overridable with the FLEET_SERIAL_FILE environment variable); a plain serial key is the fallback when no file is configured. The FleetManager only accepts a serial that was registered at provisioning or assigned by an administrator, so the name can change freely while the device stays the same machine. The brand a piece of software runs under is software-specific and passed to the app instead: App(name="datastore", branding="uttec"). Every key is optional; missing ones are simply not sent.

A software that accepts encrypted command parameters passes its public X25519 key the same way, App(name="bos-mainui", command_pubkey="<base64, 32 bytes>"). The identity is read once at start; the few fields a software may change itself -- initial_password_scheme, initial_password_changed, command_pubkey -- reach the next heartbeat through app.update_identity(...). The serial cannot be changed that way: it is the device's key and comes from the read-only file.

Release channel. The FleetManager knows the channel (nightly, candidate, stable) of every version line and returns it with the heartbeat response. A promotion changes the channel without a new build, so the software asks the fleet monitor instead of carrying it:

app.fleet.set_build_channel("candidate")   # the channel this build was delivered with
channel = app.fleet.channel()               # ("stable", "fleet") or ("candidate", "delivery") or None

The source "fleet" is the current channel, named by the FleetManager while the client is connected; "delivery" means it has not named one (no connection, or it does not know the line) and the value may be outdated - show it marked as "at delivery". The Rust client and monitor offer the same pair, set_build_channel() and channel() with ChannelSource.

With the config in place, App automatically starts the fleet monitor:

app = App(name="my-service")
app.start()  # heartbeats + diagnosis bridging start automatically

Any diagnostics reported via app.diagnosis.notify(...) are automatically forwarded to the FleetManager every 60 seconds.

See Fleet Management API reference for standalone usage, environment overrides, and endpoint details.

Adding a REST Server

Install the rest extra, then:

from brinkhaustools.rest import RestServer

server = RestServer(app=app, port=8080)
server.start()

app.wait()

Graceful Shutdown

# Block until SIGTERM/SIGINT:
app.wait()

# Or check in a loop:
while not app.shutdown.is_shutdown():
    app.shutdown.sleep(1)  # interruptible sleep

# Trigger programmatically:
app.shutdown.trigger()